Show simple item record

Title

Analysis of phthalic acid, bisphenol A and bisphenol A dimethacrylate in Mexican food cans by HPLC with evaporative light scattering detector

dc.contributor.authorGonzález Castro, Martha Irene
dc.contributor.authorOrdoñez Acevedo, Leandro Gabriel
dc.contributor.authorHerrera Vázquez, Yanoula
dc.contributor.authorRamírez Telles, Jorge Alberto
dc.contributor.authorDe León Rodríguez, Antonio
dc.contributor.editorAkadémiai Kiadó Zrt.
dc.date.accessioned2018-06-07T20:16:42Z
dc.date.available2018-06-07T20:16:42Z
dc.date.issued2013-06
dc.identifier.citationM. Gonzalez-Castro, L. Ordoñez-Acevedo, Y. Herrera-Vazquez, J. Ramirez-Telles, and A. Leon-Rodriguez. (2013). Analysis of phthalic acid, bisphenol A and bisphenol A dimethacrylate in Mexican food cans by HPLC with evaporative light scattering detector. Acta Alimentaria, 42, 229-235 .
dc.identifier.urihttp://hdl.handle.net/11627/3850
dc.description.abstract"Bisphenol A (BPA), bisphenol A dimethacrylate (BisDMA) and phthalic acid (PA) endocrine disruptors can migrate from the plastic lining of cans to foods producing serious health problems when they exceed allowable concentration limits for consumption. In this work, a method was assessed for the determination of BPA, BisDMA, and PA in vegetable food cans from Mexico using a food simulant. Those disruptors were determined by HPLC connected to an Evaporative Light Scattering Detector (ELSD), and simultaneous detection by UV-Vis detector was used for validation. The most frequently found disruptor in major concentration was PA over the range of 5.40 to 112.39 μg l−1. The samples analysed did not exceed the migration limit accepted by the US-FDA and US-EPA for bisphenols. Our results showed that HPLC-ELSD produces chromatograms with accurate signals and smaller detection limits than the UV-Vis detector for the substances analysed here."
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectEvaporative light scattering detector
dc.subjectEndocrine disruptors
dc.subjectXenoestrogen migration
dc.subjectCanned food
dc.subject.classificationTECNOLOGÍA DE LOS ALIMENTOS
dc.titleAnalysis of phthalic acid, bisphenol A and bisphenol A dimethacrylate in Mexican food cans by HPLC with evaporative light scattering detector
dc.typearticle
dc.identifier.doihttps://doi.org/10.1556/AAlim.42.2013.2.10
dc.rights.accessAcceso Abierto


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 Internacional