Mostrar el registro sencillo del ítem
Título
Synthesis of Bamboo-like Multiwall Carbon Nanotube–Poly(Acrylic Acid-co-Itaconic Acid)/NaOH Composite Hydrogel and its Potential Application for Electrochemical Detection of Cadmium(II)
dc.contributor.author | Cházaro Ruiz, Luis Felipe | |
dc.contributor.author | Olvera Sosa, Miguel | |
dc.contributor.author | Vidal García, Gabriela | |
dc.contributor.author | Rangel Méndez, José René | |
dc.contributor.author | Palestino, Gabriela | |
dc.contributor.author | Pérez Rodríguez, Fátima | |
dc.contributor.author | Zhang, Wei | |
dc.date.accessioned | 2021-04-26T19:14:24Z | |
dc.date.available | 2021-04-26T19:14:24Z | |
dc.date.issued | 2020 | |
dc.identifier.citation | Chazaro-Ruiz, L.F.; Olvera-Sosa, M.; Vidal, G.; Rangel-Mendez, J.R.; Palestino, G.; Perez, F.; Zhang, W. Synthesis of Bamboo-like Multiwall Carbon Nanotube–Poly(Acrylic Acid-co-Itaconic Acid)/NaOH Composite Hydrogel and its Potential Application for Electrochemical Detection of Cadmium(II). Biosensors 2020, 10, 147. https://doi.org/10.3390/bios10100147 | |
dc.identifier.uri | http://hdl.handle.net/11627/5614 | |
dc.description.abstract | "A poly(acrylic acid-co-itaconic acid) (PAA-co-IA)/NaOH hydrogel containing bamboo-type multiwall carbon nanotubes (B-MWCNTs) doped with nitrogen (PAA-co-IA/NaOH/B-MWCNTs) was synthesized and characterized by SEM, absorption of water, point of zero charges, infrared spectroscopy, thermogravimetric analysis, and differential scanning calorimetry. The possible use of the PAA-co-IA/NaOH/B-MWCNT hydrogel as an electrode modifier and pre-concentrator agent for Cd(II) sensing purposes was then evaluated using carbon paste electrodes via differential pulse voltammetry. The presence of the B-MWCNTs in the hydrogel matrix decreased its degree of swelling, stabilized the structure of the swollen gel, and favored the detection of 3 ppb Cd(II), which is comparable to the World Health Organization’s allowable maximum value in drinking water. A calibration curve was obtained in the concentration range of 2.67 × 10−8 to 6.23 × 10−7 M (i.e., 3 and 70 ppb) to determine a limit of detection (LOD) of 19.24 μgL−1 and a sensitivity of 0.15 μC ppb−1. Also, the Zn(II), Hg(II), Pb(II) and Cu(II) ions interfered moderately on the determination of Cd(II)." | |
dc.publisher | MDPI | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Hydrogel | |
dc.subject | Copolymer | |
dc.subject | Carbon nanotubes | |
dc.subject | Composite | |
dc.subject | Carbon杙aste electrode | |
dc.subject | Cadmium (II) detection | |
dc.subject.classification | QUÍMICA | |
dc.title | Synthesis of Bamboo-like Multiwall Carbon Nanotube–Poly(Acrylic Acid-co-Itaconic Acid)/NaOH Composite Hydrogel and its Potential Application for Electrochemical Detection of Cadmium(II) | |
dc.type | article | |
dc.identifier.doi | https://doi.org/10.3390/bios10100147 | |
dc.rights.access | Acceso Abierto |