Mostrar el registro sencillo del ítem

Título

Statistically coherent calibration of X-ray fluorescence spectrometry for major elements in rocks and minerals

dc.contributor.authorVerma, Surendra Pal
dc.contributor.authorVerma, Sanjeet Kumar
dc.contributor.authorRivera Gómez, María Abdelaly
dc.contributor.authorTorres Sánchez, Darío
dc.contributor.authorDíaz González, Lorena
dc.contributor.authorAmezcua Valdez, Alejandra
dc.contributor.authorRivera Escoto, Beatriz Adriana
dc.contributor.authorRosales Rivera, Mauricio
dc.contributor.authorArmstrong Altrin, John Selvamony
dc.contributor.authorLópez Loera, Héctor
dc.contributor.authorVelasco Tapia, Fernando
dc.contributor.authorPandarinath, Kailasa
dc.date.accessioned2019-08-26T23:12:06Z
dc.date.available2019-08-26T23:12:06Z
dc.date.issued2018
dc.identifier.citationSurendra P. Verma, Sanjeet K. Verma, M. Abdelaly Rivera-Gómez, et al., “Statistically Coherent Calibration of X-Ray Fluorescence Spectrometry for Major Elements in Rocks and Minerals,” Journal of Spectroscopy, vol. 2018, Article ID 5837214, 13 pages, 2018. https://doi.org/10.1155/2018/5837214.
dc.identifier.urihttp://hdl.handle.net/11627/5122
dc.description.abstract"We applied both the ordinary linear regression (OLR) and the new uncertainty weighted linear regression (UWLR) models for the calibration and comparison of a XRF machine through 59 geochemical reference materials (GRMs) and a procedure blank sample. The mean concentration and uncertainty data for the GRMs used for the calibrations (Supplementary Materials) (available here) filewere achieved from an up-to-date compilation of chemical data and their processing from well-known discordancy and significance tests. The drift-corrected XRF intensity and its uncertainty were determined from mostly duplicate pressed powder pellets. The comparison of the OLR (linear correlation coefficient ?0.9523–0.9964 and 0.9771–0.9999, respectively, for before and after matrix correction) and UWLR models (?0.9772–0.9976 and 0.9970–0.9999, respectively) clearly showed that the latter with generally higher values of is preferable for routine calibrations of analytical procedures. Both calibrations were successfully applied to rock matrices, and the results were generally consistent with those obtained in other laboratories although the UWLR model showed mostly narrower confidence limits of the mean (slope and intercept) or lower uncertainties than the OLR. Similar sensitivity (?2.69–46.17?kc·s?1·%?1 for the OLR and ?2.78–59.69?kc·s?1·%?1 for the UWLR) also indicated that the UWLR could advantageously replace the OLR model. Another novel aspect is that the total uncertainty can be reported for individual chemical data. If the analytical instruments were routinely calibrated from the UWLR model, this action would make the science of geochemistry more quantitative than at present."
dc.publisherHindawi Publishing Corporation
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectWeighted least-squares
dc.subjectGeochemical reference samples
dc.subjectNeutron-activation analysis
dc.subjectFitting straight-lines
dc.subjectTrace-elements
dc.subject1987 compilation
dc.subjectReplicated observations
dc.subjectQuality-control
dc.subjectRegression
dc.subjectXRF
dc.subject.classificationBIOQUÍMICA
dc.titleStatistically coherent calibration of X-ray fluorescence spectrometry for major elements in rocks and minerals
dc.typearticle
dc.identifier.doihttps://doi.org/10.1155/2018/5837214
dc.rights.accessAcceso Abierto


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 Internacional